Specialist engineering for battery cell manufacturing plants and Gigafactories — dry room HVAC design (dew points to −60°C), NFPA 855 lithium-ion fire protection, process utility MEP, clean room engineering, and end-to-end Gigafactory PMC.
Gigafactory Engineering Expertise
What We Deliver
Dry rooms are the defining engineering challenge of any Gigafactory — dew point control to as low as −60°C dew point.
- Dew point analysis — determining target dew point class for each manufacturing zone
- Dehumidification system selection — rotor dehumidifiers, dual-stage dehumidification
- Supply air condition calculation — moisture load analysis, air flow rate determination
- Make-up air handling unit (MAHU) design — pre-conditioning before dehumidification
- Recirculation air handling unit (RAHU) design — internal loop control
- Chilled water system design for dehumidification rotors and cooling coils
- HVAC load calculation — sensible heat, latent heat, process loads
- Energy consumption modelling — annual dry room HVAC energy estimate
- Controls philosophy — dew point control, temperature control, pressurisation
Gigafactories require an extensive range of process utilities for cell manufacturing — all designed, sized, and coordinated by KVRM.
- Compressed dry air (CDA) — ultra-dry air to ISO 8573 Class 1.2.1
- Deionised / ultrapure water (DI water / UPW) — generation and distribution loop
- Vacuum system design — process vacuum for slurry mixing, coating, calendering
- Cooling water system — chilled water and process cooling water (PCW) loops
- Nitrogen gas system — blanketing for electrode and electrolyte handling
- NMP solvent recovery system — HVAC for solvent recovery
- HT/LT electrical distribution — power for formation, ageing, and process equipment
- Earthing and static control system — anti-static flooring, ESD protection
Lithium-ion battery fires present unique hazards — thermal runaway, gas venting, re-ignition risk — all addressed in our NFPA 855 compliant designs.
- NFPA 855 compliance — Standard for Stationary Energy Storage Systems
- Fire protection strategy — suppression, ventilation, separation, detection philosophy
- Smoke detection system design for manufacturing and storage areas
- Sprinkler system design for cell manufacturing and module assembly
- Gas venting and exhaust system for thermal runaway events
- Battery storage area protection — rack sprinkler systems, flood systems
- Fire barrier and compartmentation strategy for high-energy storage areas
- Emergency response plan support — HAZMAT considerations
Some battery manufacturing processes require controlled cleanliness — KVRM designs the complete classified environment alongside dry room and HVAC systems.
- Electrode manufacturing — particle contamination control strategy
- Cell assembly — cleanroom classification for winding and stacking processes
- ISO 14644 classification and airflow design for applicable zones
- HVAC system design — temperature and humidity control alongside dew point control
- HEPA filtration where particulate contamination control is required
Gigafactories are major energy consumers — energy management is both a cost and ESG issue.
- Total plant energy model — production-normalised energy consumption targets
- Dry room energy optimisation — heat recovery, free cooling
- Formation and ageing energy management — charge/discharge efficiency optimisation
- Renewable energy integration — rooftop solar PV sizing and yield modelling
- ISO 50001 energy management system implementation support
- Carbon footprint reporting — Scope 2 (purchased electricity) reduction strategy
End-to-end PMC for Gigafactory construction projects.
- Pre-FEED and FEED stage PMC — basis of design, contractor selection, value engineering
- EPC stage oversight — schedule management, QA/QC, cost control, site supervision
- Dry room qualification and HVAC commissioning oversight — dew point performance testing
- Utility system commissioning — UPW, CDA, chilled water, vacuum systems
- Mechanical completion and handover documentation management
Applicable Standards — Battery Manufacturing
- NFPA 855 — Stationary Energy Storage Systems
- NFPA 13 — Automatic Sprinkler Systems
- IEC 62619 — Safety Requirements for Secondary Lithium Cells
- UN 38.3 — Transport Testing for Lithium Batteries
- ATEX / IECEx — Hazardous Area Classification
- ISO 14644 — Cleanroom Classification
- ISO 8573 — Compressed Air Quality
- ISO 50001 — Energy Management Systems
- IEC 61511 — Safety Instrumented Systems
- EU Battery Regulation 2023/1542