Data Centre
Engineering Services
Specialist engineering design for data centres β from hyperscale campus developments to colocation facilities and enterprise data rooms. Critical power, precision cooling, fire suppression, MEP BIM, and PUE management β always TIA-942 compliant.
Data Centre Engineering Expertise
What We Deliver
Reliable, resilient power supply is the defining engineering challenge in data centre design.
- UPS system design β N, N+1, 2N redundancy configurations
- HT/LT power distribution β substation sizing, ring main unit, transformer specification
- Generator sizing and fuel storage β N+1 or 2N diesel/gas backup
- Automatic transfer switching (ATS) and static transfer switch (STS) specification
- PDU (Power Distribution Unit) design and branch circuit layout
- Busbar trunking system (BTS) design for floor-level power distribution
- Load schedule and maximum demand calculation (ETAP)
- Power monitoring system β branch circuit monitoring, DCIM integration
Precision cooling keeps servers within thermal parameters β designed and modelled before construction begins.
- Chilled water system design β primary/secondary/tertiary loops, variable primary flow
- CRAC/CRAH unit selection and placement for hot aisle/cold aisle containment
- In-row cooling and overhead cooling for high-density server racks
- Cooling tower and chiller plant design β free cooling integration
- CFD thermal analysis β identifying hotspots before build
- Containment system design β HAC or CAC
- Airside economiser design and free cooling hours calculation
- Chilled water pipe sizing and pump selection β variable flow systems
- DOAS (Dedicated Outside Air System) for fresh air and humidity control
Data centre fire suppression must protect equipment without water damage β every system hydraulically calculated to NFPA standards.
- Clean agent systems β FM-200 (HFC-227ea), Novec 1230 (FK-5-1-12)
- Inert gas systems β INERGEN, Argon, IG-541 (NFPA 2001 compliant)
- COβ system design for UPS rooms and high-value equipment spaces (NFPA 12)
- VESDA aspirating smoke detection system layout
- Water mist system design as alternative to gaseous suppression (NFPA 750)
- Pre-action dry pipe sprinkler system for IT halls
- Hydraulic calculations for all fire suppression systems to NFPA standards
- Fire pump sizing and system design β NFPA 20
Fully coordinated REVIT BIM models eliminating design clashes before construction.
- REVIT MEP model β power, cooling, fire protection, containment in single coordinated model
- Clash detection and interference checking β multi-discipline RFI reduction
- Cable management system design and routing β overhead trays, raised floor pathways
- Containment system coordination β hot aisle/cold aisle within REVIT model
- Coordinated drawings β ceiling plans, riser diagrams, section views
- Material take-off (MTO) generation for procurement and tendering
PUE reduction directly reduces operating cost and improves sustainability metrics.
- PUE baseline calculation and target PUE modelling
- Cooling efficiency improvement β partial load performance, economiser hours
- Power system efficiency β UPS efficiency curves, transformer losses
- Lighting and ancillary load reduction
- DCIM integration strategy
- ISO/IEC 30134 energy efficiency metric reporting
- Annual energy cost model β full year simulation including seasonal variation
Owner’s representative services for data centre construction projects.
- Pre-construction β design coordination, contractor procurement, value engineering
- Construction stage β site supervision, QA/QC, programme management
- Commissioning stage β SMSTS, CMSTS, IMTS execution and documentation management
- Acceptance testing β IT load bank testing, UPS walkthrough, generator tests
Applicable Standards β Data Centres
- TIA-942-B β Data Centre Infrastructure (Tier IβIV)
- ASHRAE TC 9.9 β Thermal Guidelines for Data Processing
- BICSI 002 β Data Centre Design & Implementation
- ISO/IEC 30134 β Data Centre Energy Efficiency Metrics (PUE, WUE)
- EN 50600 β European Data Centre Standards
- NFPA 2001 β Clean Agent Fire Suppression Systems
- NFPA 70 (NEC) / IS Codes β Electrical Systems
- IEC 62040-3 β UPS Performance Classification (VFI, VI, VFD)
- NFPA 750 β Water Mist Fire Protection Systems
- NFPA 20 β Fire Pump Installations
Explore Our Engineering Services
Our data centre engineering team responds within 24 hours.